1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
|
local proto = Proto("t937", "T-937/M Serial Control")
local FUN_TABLE = {
[0x01] = "O_CONNECT",
[0x02] = "O_TEMPS",
[0x03] = "O_READ",
[0x06] = "O_ACK_WRITE",
[0x08] = "C_SET_HEAT",
[0x0d] = "C_SET_COOL",
[0x10] = "C_STARTSTOP",
[0x11] = "C_REQ_READ",
[0x20] = "C_WRITE",
[0xf1] = "C_ACK_CONNECT",
[0xf2] = "C_ACK_READ",
}
proto.experts.checksum = ProtoExpert.new("t937.checksum",
"T937 Checksum Error",
expert.group.CHECKSUM, expert.severity.ERROR
)
proto.fields.addr = ProtoField.uint16("t937.address", "Address", base.HEX)
proto.fields.fun = ProtoField.uint8("t937.function", "Function", base.HEX, FUN_TABLE)
proto.fields.len = ProtoField.uint8("t937.length", "Data Length", base.DEC)
proto.fields.checksum = ProtoField.uint16("t937.checksum", "Message Checksum", base.HEX)
proto.fields.conn_status = ProtoField.uint16("t937.conn_status", "Connection Status", base.HEX, {
[0x0100] = "CONNECTING",
[0x0200] = "CONNECTED",
})
proto.fields.temp1 = ProtoField.uint16("t937.temp1", "Chamber Temp 1", base.UNIT_STRING, {"°C"})
proto.fields.temp2 = ProtoField.uint16("t937.temp2", "Chamber Temp 2", base.UNIT_STRING, {"°C"})
proto.fields.temp3 = ProtoField.uint16("t937.temp3", "Control Board Temp", base.UNIT_STRING, {"°C"})
proto.fields.pwm = ProtoField.uint8("t937.pwm", "PWM", base.HEX)
proto.fields.pwm_mode = ProtoField.uint8("t937.pwm_mode", "PWM Mode", base.HEX, {
[0x44] = "ON",
[0x88] = "OFF",
})
proto.fields.profile = ProtoField.uint8("t937.profile_num", "Profile Number", base.DEC)
proto.fields.profile_dur = ProtoField.uint16("t937.profile_dur", "Profile Duration", base.UNIT_STRING, {"s"})
proto.fields.profile_temps = ProtoField.ubytes("t937.profile_temps", "Profile Temperatures")
proto.fields.startstop = ProtoField.uint8("t937.startstop", "Start/Stop", base.HEX, {
[0x11] = "START",
[0x22] = "STOP",
})
proto.fields.data = ProtoField.bytes("t937.data", "Raw Data")
local function try_dissect(bytes, pinfo, tree)
-- minimum len is header + checksum
if bytes:len() < 4 + 2 then return end
local raw_len = bytes:uint(3, 1)
if bytes:len() < 4 + raw_len + 2 then return end
local buffer = bytes:subset(0, 4+raw_len+2):tvb("T-937 Frame")
local sub = tree:add(proto, buffer())
local i = 0
sub:add_packet_field(proto.fields.addr, buffer(0, 2), ENC_BIG_ENDIAN)
local funf, fun, i = sub:add_packet_field(proto.fields.fun, buffer(2, 1), ENC_BIG_ENDIAN)
sub:add_packet_field(proto.fields.len, buffer(3, 1), ENC_BIG_ENDIAN)
local data = buffer(4, raw_len)
sub:add_packet_field(proto.fields.data, data, ENC_BIG_ENDIAN)
local csf, cs = sub:add_packet_field(proto.fields.checksum, buffer(4+raw_len), ENC_BIG_ENDIAN)
local sum = 0
for i=0,4+raw_len-1 do
sum = sum + buffer(i, 1):uint()
end
if sum ~= cs then
csf:add_proto_expert_info(proto.experts.checksum, string.format(
"expected 0x%04x, got 0x%04x", cs, sum
))
end
local fun_name = FUN_TABLE[fun]
pinfo.cols.info:set("T937 " .. (fun_name or ""))
if fun_name then
sub = sub:add(data, fun_name)
end
if fun_name == "O_CONNECT"
or fun_name == "C_ACK_CONNECT" then
sub:add(proto.fields.conn_status, data())
elseif fun_name == "O_TEMPS" then
sub:add(proto.fields.temp1, data(0,2))
sub:add(proto.fields.temp2, data(2,2))
sub:add(proto.fields.temp3, data(4,2))
elseif fun_name == "C_PWM_HEAT"
or fun_name == "C_PWM_COOL" then
sub:add(proto.fields.pwm, data(0,1))
sub:add(proto.fields.pwm_mode, data(1,1))
elseif fun_name == "C_STARTSTOP"
or fun_name == "C_REQ_READ" then
sub:add(proto.fields.profile, data(0,1), data(0,1):uint()+1)
sub:add(proto.fields.startstop, data(1,1))
elseif fun_name == "C_WRITE"
or fun_name == "O_READ" then
local len = data(0,2):uint() * 3
sub:add(proto.fields.profile, data(2,1), data(2,1):uint()+1)
sub:add(proto.fields.profile_dur, data(9,2), len)
sub:add(proto.fields.profile_temps, data(4,2))
end
return buffer:len()
end
local state
function proto.init()
state = {
error = {},
rest = {
[P2P_DIR_SENT] = ByteArray.new(),
[P2P_DIR_RECV] = ByteArray.new(),
},
buffers = {},
last_number = -1,
}
end
function proto.dissector(_buf, pinfo, tree)
local buffers = state.buffers[pinfo.number]
if buffers then
for _,buffer in ipairs(buffers) do
try_dissect(buffer, pinfo, tree)
end
return true
end
local err = state.error[pinfo.p2p_dir]
if err then
if state.last_number == pinfo.number then
error(err)
else
return
end
end
if state.last_number >= pinfo.number then
error(string.format(
"dissection order not increasing: %d >= %d",
state.last_number, pinfo.number
))
end
local rest = state.rest[pinfo.p2p_dir]
rest:append(_buf:bytes())
buffers = {}
while rest:len() > 0 do
local ok, len = pcall(try_dissect, rest, pinfo, tree)
if not ok then
state.error[pinfo.p2p_dir] = len
state.last_number = pinfo.number
print(len)
error(len)
elseif not len then
break
end
table.insert(buffers, rest:subset(0, len))
if len == rest:len() then
rest = ByteArray.new()
break
end
rest = rest:subset(len, rest:len() - len)
end
state.rest[pinfo.p2p_dir] = rest
state.buffers[pinfo.number] = buffers
state.last_number = pinfo.number
return true
end
pcall(proto.register_heuristic, proto, "ch340.serial_data", proto.dissector)
pcall(proto.register_heuristic, proto, "pl2303.serial_data", proto.dissector)
DissectorTable.get("rtacser.data"):add_for_decode_as(proto)
|